Óbudai Egyetem Digitális Archívum
    • magyar
    • English
  • magyar 
    • magyar
    • English
  • Bejelentkezés
Megtekintés 
  •   ÓDA repozitórium kezdőoldal
  • 5. Folyóiratcikkek
  • Acta Polytechnica Hungarica
  • 3. 2023
  • 3.3. 2023 Volume 20, Issue No. 8.
  • Megtekintés
  •   ÓDA repozitórium kezdőoldal
  • 5. Folyóiratcikkek
  • Acta Polytechnica Hungarica
  • 3. 2023
  • 3.3. 2023 Volume 20, Issue No. 8.
  • Megtekintés
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development of a Research Testbed for Intraoperative Optical Spectroscopy Tumor Margin Assessment

Thumbnail
Megtekintés/Megnyitás
Morton_Connolly_Groves_Sunderland_Ungi_Jamzad_Kaufmann_Ren_Rudan_Fichtinger_Mousavi_137.pdf (1.019MB)
Metaadat
Teljes megjelenítés
Link a dokumentumra való hivatkozáshoz:
http://hdl.handle.net/20.500.14044/38726
Gyűjtemény
  • 3.3. 2023 Volume 20, Issue No. 8. [16]
Absztrakt
Surgical intervention is a primary treatment option for early-stage cancers. However, the difficulty of intraoperative tumor margin assessment contributes to a high rate of incomplete tumor resection, necessitating revision surgery. This work aims to develop and evaluate a prototype of a tracked tissue sensing research testbed for navigated tumor margin assessment. Our testbed employs diffuse reflection broadband optical spectroscopy for tissue characterization and electromagnetic tracking for navigation. Spectroscopy data and a trained classifier are used to predict tissue types. Navigation allows these predictions to be superimposed on the scanned tissue, creating a spatial classification map. We evaluate the real-time operation of our testbed using an ex vivo tissue phantom. Furthermore, we use the testbed to interrogate ex vivo human kidney tissue and establish a modeling pipeline to classify cancerous and non-neoplastic tissue. The testbed recorded latencies of 125 ± 11 ms and 167 ± 26 ms for navigation and classification respectively. The testbed achieved a Dice similarity coefficient of 93%, and an accuracy of 94% for the spatial classification. These results demonstrated the capabilities of our testbed for the real-time interrogation of an arbitrary tissue volume. Our modeling pipeline attained a balanced accuracy of 91% ± 4% on the classification of cancerous and non-neoplastic human kidney tissue. Our tracked tissue sensing research testbed prototype shows potential for facilitating the development and evaluation of intraoperative tumor margin assessment technologies across tissue types. The capacity to assess tumor margin status intraoperatively has the potential to increase surgeon confidence in complete tumor resection, thereby reducing the rates of revision surgeries.
Cím és alcím
Development of a Research Testbed for Intraoperative Optical Spectroscopy Tumor Margin Assessment
Szerző
Morton, David
Connolly, Laura
Groves, Leah
Sunderland, Kyle
Ungi, Tamas
Jamzad, Amoon
Kaufmann, Martin
Ren, Kevin
Rudan, John F.
Fichtinger, Gabor
Mousavi, Parvin
Megjelenés ideje
2023
Hozzáférés szintje
Open access
ISSN, e-ISSN
1785-8860
Nyelv
en
Terjedelem
19 p.
Tárgyszó
computer-assisted intervention, tumor margin assessment, intraoperative optical spectroscopy, tissue conserving surgery, machine learning
Változat
Kiadói változat
Egyéb azonosítók
DOI: 10.12700/APH.20.8.2023.8.9
A cikket/könyvrészletet tartalmazó dokumentum címe
Acta Polytechnica Hungarica
A forrás folyóirat éve
2023
A forrás folyóirat évfolyama
20. évf.
A forrás folyóirat száma
8. sz.
Műfaj
Tudományos cikk
Tudományterület
Orvostudományok - multidiszciplináris orvostudományok
Egyetem
Óbudai Egyetem

DSpace software copyright © 2002-2016  DuraSpace
Kapcsolat | Visszajelzés
Theme by 
Atmire NV
 

 

Böngészés

A teljes ÓDA-banKategóriák és gyűjteményekMegjelenés dátumaSzerzőCímTárgyszóA gyűjteménybenMegjelenés dátumaSzerzőCímTárgyszó

Személyes felhasználói fiók

BejelentkezésRegisztráció

DSpace software copyright © 2002-2016  DuraSpace
Kapcsolat | Visszajelzés
Theme by 
Atmire NV