The Development of a Motion-Tracking System to Assess the Recovery Level for Stroke Survivors

Thumbnail
Megtekintés/Megnyitás
Nguyen_Nguyen_Ha_Hoang_Bui_Tien_149.pdf (1.282MB)
Metaadat
Teljes megjelenítés
Link a dokumentumra való hivatkozáshoz:
http://hdl.handle.net/20.500.14044/32543
Gyűjtemény
  • Acta Polytechnica Hungarica [98]
Absztrakt
Stroke is a widespread and perilous condition globally, necessitating effective rehabilitation assessment methods. Presently, clinicians rely on manual observation or costly equipment like motion capture systems to evaluate stroke patients’ recovery progress. This study introduces a streamlined measurement system designed for assessing lower limb function recovery in stroke patients. The system employs wearable IMU (Inertial Measurement Unit) sensor modules strategically placed on the lower limbs to capture joint angles. An algorithm processes sensor data to calculate precise joint angles. To counteract environmental interference affecting IMU sensors, a Kalman filter is implemented to minimize errors, providing real-time adjustments for sensor accuracy. Experimental validation, using exercises and criteria from the FUGL-MEYER Assessment, a widely adopted method for evaluating stroke patients’ physical performance, was conducted to compare the proposed system with the VICON motion capture system. Results demonstrated close alignment between the two systems, affirming the proposed system’s reliability, applicability, and practicality for real-life medical evaluations. Importantly, the proposed system offers a cost-effective and portable alternative for measuring joint angles, maintaining effectiveness and precision. In summary, this system offers a straightforward design, easy installation, and affordable hardware, making it a viable and practical solution for evaluating lower limb rehabilitation in stroke patients.
Cím és alcím
The Development of a Motion-Tracking System to Assess the Recovery Level for Stroke Survivors
Szerző
Nguyen, Thanh-Trung
Nguyen, Quang-Duy
Ha, Minh-Quang
Hoang, Xuan-Tung
Megjelenés ideje
2024
Hozzáférés szintje
Open access
ISSN, e-ISSN
1785-8860
Nyelv
en
Terjedelem
20 p.
Tárgyszó
imu sensors, kalman filter, fugl-meyer assessment, lowerlimb, vicon motion capture system
Változat
Kiadói változat
Egyéb azonosítók
DOI: 10.12700/APH.21.9.2024.9.2
A cikket/könyvrészletet tartalmazó dokumentum címe
Acta Polytechnica Hungarica
A forrás folyóirat éve
2024
A forrás folyóirat évfolyama
21. évf.
A forrás folyóirat száma
9. sz.
Műfaj
Tudományos cikk
Tudományterület
Műszaki tudományok - multidiszciplináris műszaki tudományok
Egyetem
Óbudai Egyetem

DSpace software copyright © 2002-2016  DuraSpace
Kapcsolat | Visszajelzés
Theme by 
Atmire NV
 

 

Böngészés

A teljes DSpace-benKategóriák és gyűjteményekMegjelenés dátumaSzerzőCímTárgyszóA gyűjteménybenMegjelenés dátumaSzerzőCímTárgyszó

Személyes felhasználói fiók

BejelentkezésRegisztráció

DSpace software copyright © 2002-2016  DuraSpace
Kapcsolat | Visszajelzés
Theme by 
Atmire NV