This paper focuses on the analysis of two towers of an industrial plant exhibiting extreme deflection during service loads under heavy wind conditions. The towers are 90 m and 35 m in height, respectively and are interconnected with structural steel operating platforms. The nuts have flown off at some bolted joints in the interconnecting steel structure due to high stress induced by deflections. The deflections measured at the structural steel towers had nearly twice the value permitted by the respective standard in the case of the 90 m high tower and approached the value permitted by the standard in the case of the 35 m high tower. The herein detailed complex study - covering the strength analysis of the towers, the analysis of wind effects, and the review of the foundations - has been elaborated in order to determine the causes and consequences of the experienced deflections at the plant as well as to conclude the eventual actions to be taken. The primary consideration for the conduction of the tests and analyses the determination of the eventual actions to be taken was to retain the towers and not to have them demolished.hu_HU
dc.formatPDFhu_HU
enhu_HU
Can the tower be retainedhu_HU
Open accesshu_HU
Óbudai Egyetemhu_HU
Budapesthu_HU
Ybl Miklós Építéstudományi Karhu_HU
Óbudai Egyetemhu_HU
Műszaki tudományok - építészmérnöki tudományokhu_HU
Dynamic wind effecthu_HU
Karman effecthu_HU
change in groundwater levelhu_HU
deflectionhu_HU
high towershu_HU
Tudományos cikkhu_HU
YBL Journal of Built Environmenthu_HU
local.tempfieldCollectionsFolyóiratcikkekhu_HU
Kiadói változathu_HU
14 p.hu_HU
2014
1. sz.hu_HU
2. évf.hu_HU
2014hu_HU
Óbudai Egyetemhu_HU


A dokumentumhoz tartozó fájlok

Thumbnail

A dokumentum a következő gyűjtemény(ek)ben található meg

Rövidített megjelenítés